仅供临床科研使用
销售价格: N/A
商品编号: AI-0134-0395
软件语言: 英文
器械分类: II
生产厂家: ImageBiopsy Lab
公司网址: https://www.imagebiopsy.com/
认证信息: FDA
系统要求: Windows
交付方式: 下载安装
  • 软件概览
  • 推荐配置
  • 典型病例
  • 软件教程
  • 临床文献
  • 用户评价
  • 产品彩页

软件概览

LAMA™

Automated Assessment of Long Leg Radiographs


Problems

Currently, pre-and post-total knee arthroplasty (TKA) lower limb alignment is assessed manually or with the aid of interactive software applications, resulting in high intra- and inter-reader variability, poor reproducibility and calibration errors.

1754200694726.png


Solutions

Fully-automated measurements aid users in quantifying limb-length discrepancy and quantitative knee alignment parameters on uni- and bilateral AP full leg radiographs.

LAMA™ is here to support you!

Accurate & Precise

Deep learning technology enables automated accurate and precise measurement of knee alignment within ≤1° and leg-length discrepancy within ≤ 2mm [1]

Fast

Reading and reporting time of lower limb deformities radiographs can be reduced from 3 minutes to <1 minute (more than 3x faster) resulting in more time for patient care [2]

Implant Support

IB Lab LAMA™ now supports radiographs with total hip and total knee implants, providing 13 standardized measurements for both pre- and post-surgery radiographs [3]

1754200708974.png


Product description

LAMA™ uses deep learning technology to provide precise fully-automated geometric length and angle measurements of the lower limb on full leg X-ray images. The outputs aid healthcare professionals who are interested in the analysis of leg-length discrepancy and knee alignment in adult patients with suspected or present deformities of the lower extremities. 

The user does not interact directly with IB Lab LAMA™ except to accept or reject the generated report findings via cleared third party medical viewers. The measurements are compared to fixed predetermined norm-ranges, based on standard state of the art clinical practices hard-coded into the software. Outputs are summarised in reports that can be viewed on any cleared medical DICOM viewer.


Findings

IB Lab LAMA™ provides the following measurements:

mechanical axis deviation

● full leg length

● femur length

● tibia length

● leg length discrepancy

● hip knee ankle angle

● anatomical tibiofemoral angle

● anatomical mechanical angle

● joint-line convergence angle

● mechanical lateral proximal femoral angle

● mechanical lateral distal femoral angle

● mechanical medial proximal tibia angle

● mechanical lateral distal tibia angle


Intended use

IB Lab LAMA™ is a fully-automated radiological image processing software device intended to aid users in the measurement of limb-length discrepancy and quantitative knee alignment parameters on uni- and bilateral AP full leg radiographs of individuals at least 22 years of age. It should not be used in-lieu of full patient evaluation or solely relied upon to make or confirm a diagnosis. The software device is intended to be used by healthcare professionals trained in radiology. IB Lab LAMA™ is not indicated for use on radiographs on which Ankle Arthroplasties and/or Unicompartmental Knee Arthroplasties are present.

1754200739268.png

References

[1] Clinical Study affiliated with University of Texas Southwestern Medical Center (UTSW) (K223646), 2023

[2]  Simon, S., Schwarz, G.M., Aichmair, A. et al. Fully automated deep learning for knee alignment assessment in lower extremity radiographs: a cross-sectional diagnostic study. Skeletal Radiology (2021).

[3] Schwarz et al. Artificial intelligence enables reliable and standardized measurements of implant alignment in long leg radiographs with total knee arthroplasties. Knee Surg Sports Traumatol Arthrosc. (KSSTA) 2022 doi: 10.1007/s00167-022-07037-9

[4] IB Lab US Market Survey 2020

G. McDaniel, K.L. Mitchell, C. Charles, V.B. Kraus: A comparison of five approaches to measurement of anatomic knee alignment from radiographs, November 16, 2009.

James M Hartford, Michael J Bellino: The learning curve for the direct anterior approach for total hip arthroplasty: a single surgeon’s first 500 cases, September 19, 2017.

World Health Organization: Increasing complexity of medical technology and consequences for training and outcome of care, August 2010.

IB Lab LAMA Clinical Validation study