仅供临床科研使用
InterView™ XP Processing Software 了解更多
销售价格: N/A
商品编号: AS-0251-0663
软件语言: 英文
器械分类: II
生产厂家: Mediso Ltd.
公司网址: https://mediso.com/global/en
认证信息: FDA
系统要求: Windows
交付方式: 下载安装
  • 软件概览
  • 推荐配置
  • 典型病例
  • 软件教程
  • 临床文献
  • 用户评价
  • 产品彩页

软件概览

InterView™ XP Processing Software

Planar, Whole-Body & SPECT Processing Software

InterView™ XP is an organ-specific dedicated planar, whole-body, and SPECT evaluation software. Procedures are implemented in correspondence with the guidelines of the most acknowledged nuclear medicine societies. The evaluation process is guided through standardized evaluation steps, and supported by specialized viewers and automated algorithms. A wide range of function-specific tools enable the measurement, manipulation, enhancement, and analysis of gamma camera images. User-defined procedure variants allow customization of the workflow. InterView™ XP features 2D and 3D iterative reconstruction of SPECT images, including Mediso-developed Tera-Tomo™ reconstruction incorporating a full scale of corrections.


Features & Benefits

All-in-one Solution for Nuclear Medicine

Vendor-neutral processing software for planar gamma camera, SPECT, and multimodality systems

Full DICOM conformance, IHE implementation

Seamless integration into any hospital information system

Stand-alone, server, or virtualized server variant

CE and FDA-approved

1753452961237.png


Wizard Like Workflow

Follows unified processing steps:

Study and procedure selection: list studies and procedures side-by-side in procedure browser

Role selection: assign image roles with automatic role assignment and integrated real-time image validator tool

Custom configuration: set study parameters and required data for processing

ROI definition: choose from a wide range of ROI tools for quick and easy definition of regions to be analyzed

Show results: visualize measurements on interactive plots and display statistics in tables

Create report: export highly customizable reports from any result page

1753452968109.png


SPECT Reconstruction

FBP, ML iteration, OS-EM, MOS-EM reconstruction algorithms combined with customizable pre- and post-filters

Chang’s post-reconstruction attenuation correction

Tera-Tomo™ 3D SPECT full-featured 3D iterative reconstruction, incorporating corrections for all the significant deteriorating factors of SPECT imaging

CT-based attenuation and scatter correction

Tera-Tomo™ 3D SPECT-Q option for quantitative image reconstruction

Parallel reconstruction and reorientation of dual studies

Enhance image quality with optional Tera-Tomo™ 2D Image Enhancement and Tera-Tomo™ 3D Bone Enhancement modules.

1753452974535.png


Image Processing Tools

Fast 2D and 3D filters in both spatial and frequency domain

Fine tune filters with the filter editor tool

Removal of disturbing high-activity areas with the clear area option

Correct images with activity, decay and scatter corrections

Fast automatic spatial registration of different modalities in the reconstruction engine

Manual or automatic motion correction for both planar and SPECT images

Manual or automatic reorientation of cardiac studies

Resample images to different pixel size

1753452980918.png


Data Visualization

Polar map (bull’s eye) display for myocardial studies

3D visualization of cardiac images including wall motion

Display condensed images to detect motion in dynamic planar images

Detect motion artefacts on SPECT projections with sinogram or linogram

Visualize important parameters of dynamic studies with parametric images

Time-activity curves, including marker tools (defining an interval) for curve fitting and parameter calculation.

Display image statistics on histograms or profile views.

1753452986449.png


Export Results and Reporting

Mark points or regions of interest with rulers or markers

Choose report contents from various result pages

Create different report templates for each procedure

Customize report structure and content to best fit the institution needs

Integrate reports of third-party software to InterView reports

Burn results to CD together with InterViewTM FUSION Lite that provides an extended toolset for image review

Export results not only in DICOM but PNG, JPEG, AVI, PDF and CSV formats.

1753452994976.png


Third-party Software Integration

Extend the functionality of InterView XP with third-party software, including:

Invia’s Corridor 4DM SPECT and PET molecular imaging packages

Cedars-Sinai QGS, QPS, and QBS packages

Emory Cardiac Toolbox SPECT and PET packages

NeuroQ brain imaging analysis software with optional normal databases.

1753453002138.png


Cardiac

Gated and non-gated myocardial perfusion SPECT protocols

Reveal reversible and fixed perfusion defects from non-gated studies

Calculate EDV, ESV, EF, wall motion and thickening from gated studies

Gated blood-pool SPECT for identifying global and regional wall motion abnormalities and estimating ventricular volumes

First pass and gated equilibrium planar blood-pool studies

Cardiac first-pass imaging to quantify left-to-right shunt, or left or right ventricular function

Gated equilibrium planar radionuclide ventriculography (ERNV) for assessing left ventricular function

Optional integration with dedicated third-party software packages including normal databases

Central Nervous System

Analyze brain perfusion SPECT studies to identify hypo- or hyper-perfused regions

Evaluate first-pass brain images to determine functional anomalies after inflammation and radioiodine therapy

Visualize and quantify striatal dopamine transport with DaTSCAN in suspected Parkinsonism

Optional module for automated analysis of brain PET or SPECT scans including [99mTc]ECD and [99mTc]HMPAO SPECT.

Thyroid and Parathyroid

Processing, visualization and calculation of thyroid uptake from [99mTc]pertechnetate scintigraphy

Measure thyroid iodine uptake and calculate dose for therapy

Thyroid I-123 Clearance

Various thyroid mass estimation methods for the whole thyroid, the left and right lobes, and nodules

Identify parathyroid adenoma or hyperplasia with dual-radiopharmaceutical parathyroid imaging

Kidney

Static Kidney procedure allows visual assessment of kidney abnormalities and quantitative measurement of split renal function

Dynamic Kidney First-Pass procedure for the examination of kidney perfusion

Renography procedure for the examination of relative function, and calculation of residual activity and output efficiency of the kidneys

Deconvolution Analysis to calculate mean transit time and output efficiency for the kidneys

Dynamic Kidney Clearance procedure is dedicated to estimate GFR/TER/ERPF values from dynamic image series

Dynamic 

1753453009207.png